Product Description
1. Temperature Shock
1.1 The test objects are battery packs and systems.
1.2 The test objects are placed in an alternating temperature environment ranging from (-40 ± 2) °C to (85 ± 2) °C, and the transition time between the two extreme temperatures is within 30 minutes. The test objects are kept in each extreme temperature environment for 8 hours, with 5 cycles. Observe for 2 hours at room temperature.
1.3 Requirements: There should be no leakage, shell rupture, fire, or explosion in the battery pack or system. The insulation resistance value after the test should not be less than 100 Ω/V. Damp Heat Cycle
2.1 The test objects are battery packs and systems.
2.2 Conduct the test Dd with reference to GB/T2423. The maximum temperature is +80 °C, and the number of cycles is 5 times. Observe for 2 hours at room temperature.
![]()
Main Parameters
Model |
|
MESS-225 |
MESS-408 |
MESS-1000 |
Performance parameters |
Temperature range |
-40-+150ºC (temperature change range: -20+80ºC): -70+150ºC (temperature change range: -55+80ºC |
Temperature fluctuation |
±0.5ºC |
Temperature deviation |
≤±2ºC |
Humidity deviation |
±3%RH (<75%RH) ±5%RH (≤75%RH) |
The rate of temperature rise and fall |
5ºC min |
Standard load |
5kg aluminum ingot |
12kg aluminum ingots |
25kg aluminum ingots |
Organization |
Outer casing |
High-strength cold-rolled steel plate double-sided fine powder baking paint |
Inner wall |
SUS#304 stainless steel 2B panel |
Insulation material |
Glass fiber + polyurethane foam |
Refrigeration system |
Refrigeration method |
Single-stage mechanical refrigeration/superimposed two-stage compressor refrigeration method |
Chiller |
Imported compressors |
Heater |
Electric heating wire heater |
Observation window (mm) |
300*400/400*600 |
Test hole (mm) |
One 50 on the left |
One 100 on the right |
Temperature sensor |
Platinum resistance pt100 |
Controller |
Original Japanese imported 7 Cun TFT Touch screen |
Recording device |
Built-in paperless recorder function (external printing available) |
Computer interface |
UCB Interface connection operation |
Internal size (cm) |
Width |
60 |
80 |
100 |
Height |
50 |
85 |
100 |
Deep |
75 |
60 |
100 |
Motor cover height |
190 |
210 |
220 |
Power supply |
Audio-visual 380V 50Hz. Sanxiang Wire Control + Grounding Wire. |
Standard configuration |
1 copy of the product instruction manual. 1 copy of the experimental report, 1 copy of the qualification certificate and 1 copy of the quality assurance certificate, 2 partitions, a set of silicone rubber soft plugs. |
Meet the configuration |
China National Standard 11158\GBT.2423\GC./T2423.1/T2423.2/GBT.24423.2GJB.1500.3\GJB.15.0 |
Notes
1. The external dimensions are determined according to the heating and cooling rate.
2. Water-cooled type (water temperature: 10-28°C, water pressure: 0.1-0.3 MPa, to ensure the cooling performance).
3. The damp heat function can be added.
4. A dry air purge system is optional.
5. The liquid nitrogen function (30°C/minute) is optional.
6. The above load is the standard load, and it can be designed according to the customer's requirements.
Company Profile
![]()
![]()
![]()
Certifications
![]()
Ship to Client's Factory
Our Partners
![]()
Packaging & Shipping
![]()